Model 2000
Convertitore di volume tipo 2 con tecnologia web programmabile, lettura a distanza e gestione dei trasmettitori di temperatura e pressione completamente digitalizzata
| Technical data | Download | ||||
| Hardware architecture |
Motorola ColdFire microprocessor 32 bits, 40 MHz - RAM data memory 16M, Flash program memory 8M, EEPROM preset memory 1M |
| Calculation gases |
Compressibility: AGA3-NX19, GOST, AGA 8 (full composition), ISO 12213, fixed Z, table Z Flow calculations: ISO 5167 (2003), AGA 3; STACA / CATS (North Sea) equation support Heating value and relative density: ISO 6976 (mass or volume based) (molar percent or mass fraction) AGA report No. 9 - US meter; AGA report No. 7 - turbine meter |
| Density | Density and relative density periodic type transmitter support - Solartron or Sarasota equations - Upstream or downstream calculation - Temperature and/or VOS compensation |
| Calculations liquids |
Simple fixed density: - Water or fuel oil (fixed K-factor) Condensate based measured density: - Oils - API chapter 11.1 tables 53A and 54A - NORSOK I-105 - API chapter 11.2.1 and 11.2.2 - ASTM-D-1250 - API MPMS 12.2.5.3 & 4 |
| Prover functions | API MPMS12.2.5.1 to 4 |
| Pulse integrity | API 5.5 level A, ISO6551 level A, pulse interpolation, dual pulse chronometry |
| Steam | ISO 5167 venturi equations |
| Wet gas | ISO 5167 orifice and venturi equations - De Leeuw correlation - Dickinson Jamieson correlation - Steven correlation - Chisholm correlation - Homogenous correlation (measured line density) |
| Station controller |
Up to 5 (optional 8) flow computers can be served - Station pressure & Temperature measurement - Distribution of Gas Data to all connected Flow Computers - Station Totals and Flow Calculations, Display and Reporting - Average Gas Data calculation - Stream flow comparison (mixed types e.g. turbine & ultrasonic) |
| Ethernet | One or more independent Ethernet ports (10/100 MHz) - Multiple protocol support, Modbus over TCP/IP, remote front panel operation - Remote diagnostics, configuration and set-up, max. 7 sessions per Ethernet port - Pass through communication support |
| Serial | Two or more isolated serial ports (RS232/RS485) programmable baud rate up to 115kB - Free programmable configuration and protocol Modbus ASCII/RTU |
| Analogue / pulse outputs |
4 analogue 4-20 mA current loops (16 bit D/A conversion max error 0.15%) per output module 12 pulse / alarm or status Opto-coupler outputs per output module |
| Inputs (per module) |
2 pulse counting / frequency inputs (5kHz) for turbine (pulse) or density input signals 2 HART transmitter loops (max. 3 transmitters per loop) 4 analogue inputs 4-20mA (24 bit A/D conversion) 1 (optional 2) direct PRT input(s) (3 or 4 wire) 3 digital status inputs |
| Power supply | 21 to 28 VDC maximum 25 VA |
| Display | Liquid crystal with backlight, large viewing area 130 x 34 mm with 240 x 64 pixels |
| Dimensions / mounting |
Custom designed and manufactured construction Dimensions 128 x 213 x 235 mm (H x W x D) Half 19” (3U) rack mounted or panel mounted |
| Temperature range |
Operating 0 to +60 °C, storage 0 to +70 °C |
| Accessories | - Rack mounted counter module (max. 4 electromechanical counters) - Printer unit using ink ribbon with integral paper rewind - 19” Rack for cabinet mounting, will hold two M2000 or one M2000 with a printer module - USB programming cable and Windows configuration software |